Sr-600 series, Instruction manual, 2d code reader (fixed type)
- Instruction Manual
- Keyence Digital Microscope Vhx 6000
- Keyence Vhx 6000 User Manual Pdf File
- Keyence Manual Download
- Keyence Vhx 6000 User Manual Pdf Download
- Keyence Vhx-6000 Manual
Read this manual before use. Keep this manual in a safe place for future reference. General cautions Take substantial safety measures to avoid any damage in the unlikely event of a problem occurring. KEYENCE cannot guarantee the functionality or performance of units that have been modified or used with specifications other than those described in this manual.
1
E SR-600-IM
Read this manual before use.
Keep this manual in a safe place for future reference.
General cautions
•
Take substantial safety measures to avoid any damage in the unlikely event of a
problem occurring.
•
KEYENCE cannot guarantee the functionality or performance of units that have been
modified or used with specifications other than those described in this manual.
•
When the SR-600 Series is used in combination with other devices, functions and
performance may be degraded, depending on the operating conditions and
surrounding environment.
•
Parts of this manual may not be used or duplicated without express permission.
•
The contents of his manual are subject to change without notice.
•
This product is just intended to detect the object(s). Do not use this product for the
purpose to protect a human body or a part of human body.
•
Instruction Manual
This product is not intended for use as explosion-proof product. Do not use this
product in hazardous location and/or potentially explosive atmosphere.
Safety precautions for laser product
The SR-600 Series uses a visible semiconductor laser, with wavelength of 660 nm, as a
target pointer for adjusting the reading position.
UL Certifications
The SR-600 Series is an UL/C-UL Listed/Recognized product.
•
File No.: E207185, Category: NRAQ/NRAQ7, Applicable standard: UL508
•
File No.: E167973, Category: NWGQ2/NWGQ8, Applicable standard: UL60950-1
Be sure to follow the specification below.
•
Use a power supply that provides Class 2 output defined in NEPA70
(NEC: National Electrical Code).
•
Pollution degree: 2
•
Overvoltage category: I
FDA (CDRH) Regulations
The SR-600 Series complies with the following FDA (CDRH) regulations.
Applicable regulations: 21 CFR Part 1040.10, Class 1 Laser Product
The classification is based on IEC60825-1 according to the Laser Notice No. 50 issued
by FDA (CDRH).
CE Marking
The SR-600 Series complies with the essential requirements of EMC Directive and Low-
voltage Directive.
The following harmonized standards are applied.
Applicable standards (EMI):
EN55011, Class A
EN55022, Class A
(EMS): EN61000-6-2
EN61000-6-1
(LVD):
EN60825-1, Class 1 Laser Product
* We conducted the test on the combination with the SR-600 series and the
communication units (N-R2/UB/R4/L1) to confirm the conformity.
FCC Regulations
The SR-600 Series complies with the following FCC EMI regulations.
•
FCC 47 CFR Part 15, Subpart B, Class A, Digital devices
Canada IC (Industry Canada) Regulations
The SR-600 Series complies with the following IC EMI regulations.
•
ICES-003, Class A, Digital apparatus
DANGER
Failure to follow instructions may lead to death or serious injury.
WARNING
Keyence Digital Microscope Vhx 6000
Failure to follow instructions may lead to injury.
CAUTION
Failure to follow instructions may lead to product damage or
malfunctions.
Note
Provides additional information on proper operations that can be
easily mistaken.
Reference
Provides advanced and useful information for operation.
Safety Information for SR-600 Series
CAUTION
Use of controls or adjustments or performance of
procedures other than those specified herein may result in
hazardous radiation exposure.
Laser pointer
Wavelength
660 nm
Output
90 μW
Pulse width
200 μs
Laser class
Class 1 laser product
IEC60825-1
WARNING
Follow the instructions mentioned in this manual. Otherwise,
injury to the human body (eyes and skin) may result.
Precautions on class 1 laser products
• Do not stare into the beam.
• Do not disassemble this product. Laser emission from
this product is not automatically stopped when it is
disassembled.
Operating Precautions
CAUTION
• Do not use a voltage other than 5VDC with the SR-600
Series. Doing so may lead to damage on the unit.
• When using the dedicated communication units (NX-50
Series, N-R2/R4/UB/L1, or DV-90 Series), use a power
supply within the appropriate range for each unit.
• Be sure to turn the power off to devices attached to the
SR-600 series when you plug or unplug the cables.
Failure to do so may cause damage to the SR-600 Series.
• Do not disassemble or modify the SR-600 Series. Doing
so may lead to damage on the unit.
• Keep the cables away from high-tension cables or power
sources. Otherwise, noise could cause malfunctions or
accidents.
• The SR-600 Series is a
precision instrument. Do
not apply shock to the
instrument or drop it. Be
especially careful when
transporting or installing
the unit.
• Do not hold the SR-600
Series by its cable. The
units may become
damaged if they strike
each other.
• Do not allow water, oil, dust, or other foreign substances
to stick to the scanner. This may cause read errors. Use a
soft, dry cloth to wipe any substances from the scanner.
(Do not use a cloth dipped in alcohol or other cleaning
substance.)
Regulations and Standards
2D Code Reader (Fixed Type)
SR-600 Series
Instruction Manual
96M11490
Keyence Vhx 6000 User Manual Pdf File
To use all available functions on this website, JavaScript must be enabled in your browser.
- English
- Models
1 - 35 of 35 products listed below
- VHX-6000
Digital Microscope - CAD Data
- Manuals
- VHX-6000
- VHX-S600E
Free-angle observation system (Z axis electric stage) - CAD Data
- Manuals
- VHX-S600E
- VHX-S600F
Z axis electric stage - Data Sheet (PDF)
- CAD Data
- Manuals
- VHX-S600F
- VHX-S650E
Free-angle observation system (XYZ electric stage) - CAD Data
- Manuals
- VHX-S650E
- VHX-S660E
Large scale free-angle observation system (XYZ electric stage) - CAD Data
- Manuals
- VHX-S660E
- VHX-6020
Camera unit - CAD Data
- Manuals
- VHX-6020
- VHX-6100
Camera unit - CAD Data
- Manuals
- VHX-6100
- VH-B100
Real Bore Lens - CAD Data
- Manuals
- VH-B100
- VH-B18
Real Bore Lens - CAD Data
- Manuals
- VH-B18
- VH-B27
Real Bore Lens - CAD Data
- Manuals
- VH-B27
- VH-B40
Real Bore Lens - CAD Data
- Manuals
- VH-B40
- VH-B55
Real Bore Lens - CAD Data
- Manuals
- VH-B55
- VH-Z00R
Standard macro/zoom lens (0.1 x to 50 x) - CAD Data
- Manuals
- VH-Z00R
- VH-Z00T
Standard macro/zoom lens (0.1 x to 50 x) - CAD Data
- Manuals
- VH-Z00T
- VH-Z100R
Universal zoom lens (100 x to 1000 x) - CAD Data
- Manuals
- VH-Z100R
- VH-Z100T
Universal zoom lens (100 x to 1000 x) - CAD Data
- Manuals
- VH-Z100T
- VH-Z100UR
DIC universal lens (100 x to 1000 x) - CAD Data
- Manuals
- VH-Z100UR
- VH-Z100UT
DIC universal lens (100 x to 1000 x) - CAD Data
- Manuals
- VH-Z100UT
- VH-Z20R
Standard zoom lens (20 x to 200 x) - CAD Data
- Manuals
- VH-Z20R
- VH-Z20T
Standard zoom lens (20 x to 200 x) - CAD Data
- Manuals
- VH-Z20T
- VH-Z20UR
DIC standard lens (20 x to 200 x) - CAD Data
- Manuals
- VH-Z20UR
- VH-Z20UT
DIC standard lens (20 x to 200 x) - CAD Data
- Manuals
- VH-Z20UT
- VH-Z250R
Dual-light high-magnification zoom lens (250 x to 2500 x) - CAD Data
- Manuals
- VH-Z250R
- VH-Z250T
Dual-light high-magnification zoom lens (250 x to 2500 x) - CAD Data
- Manuals
- VH-Z250T
- VH-Z500R
High-resolution zoom lens (500 x to 5000 x) - CAD Data
- Manuals
- VH-Z500R
- VH-Z500T
High-resolution zoom lens (500 x to 5000 x) - CAD Data
- Manuals
- VH-Z500T
- VH-Z50L
Universal lens with large working distance (50 x to 500 x) - CAD Data
- Manuals
- VH-Z50L
- VH-Z50T
Universal lens with large working distance (50 x to 500 x) - CAD Data
- Manuals
- VH-Z50T
- VH-BA
Real Bore Lens Attachment - CAD Data
- Manuals
- VH-BA
- VH-F
Fibrescope Attachment - CAD Data
- Manuals
- VH-F
- VH-K20
Variable Illumination Attachment for VH-Z20 - CAD Data
- Manuals
- VH-K20
- VH-M100E
XY Measurement System - CAD Data
- Manuals
- VH-M100E
- VH-S300
Digital Microscope - CAD Data
- Manuals
- VH-S300
- VH-S30B
Free-angle Observation System Base Unit - CAD Data
- Manuals
- VH-S30B
- VH-S30F
Free-angle Observation System Lens Holder - CAD Data
- Manuals
- VH-S30F
Keyence Manual Download
- Downloads:
More Series In Digital Microscopes
Types In Microscopes
KEYENCE INDIA PVT. LTD. SKCL Triton Square, 1st Floor, No. C3 to C7,
Thiru-Vi-Ka Industrial Estate, Guindy, Chennai – 600032,
Tamil Nadu, India
Phone: 1-800-103-0090
E-mail: info@keyence.co.in
Career Opportunities: KEYENCE Career Site
Keyence Vhx 6000 User Manual Pdf Download
Copyright (C) 2019 KEYENCE CORPORATION. All Rights Reserved.