Chroma 62006p-100-25 User Manual

Advertising

Programmable

Chroma’s 62000P Programmable DC Power Supply offers many advantages including a constant power operating envelope, precision readback of output current and voltage, output trigger signals as well as the ability to create complex DC transients waveforms to test device behavior to spikes, drops, and other voltage deviations. Chroma agrees to repair or replace any assembly. Interference in which case the user may be required to take adequate measures. Failure to comply with these precautions or specific WARNINGS given elsewhere in this manual will violate safety standards of design, manufacture, and intended use of. The 62006P-100-25 allows for 100 user programmable sequences with time settings ranging from 5ms to 15000s, voltage /current slew rate control and 8 bit TTL output for automated test applications.

DC Power Supply

Chroma's new 62000P Series of programmable DC
power supplies offer many unique advantages
for ATE integration and testing. These advantage
include a constant power operating envelope,
precision readback of output current and voltage,
output trigger signals as well as the ability to
create complex DC transients waveforms to
test device behavior to spikes, drops, and other
voltage deviations.Designed for automated
testing DC-DC converters and similar products,
the 62000P sets a new standard for high accuracy
programmable DC supplies.

The 62000P Series includes 12 different models
ranging from 600W to 5000W, up to 120A and up
to 600V. Due to their constant power operating
envelope a single instrument can provide both
high voltage/low current AND low voltage/high
current thereby reducing the number of supplies
needed in typical ATE applications.

The 62000P Series also includes 16 bit readback
capability for accurate voltage and current
readings. This means systems no longer need
complex shunt/multiplexers to make accurate

readings of the UUT's input parameters. The
instruments also include I/O ports providing 8
bit TTLs, DC-ON, fault output signal and remote

inhibit as well as a output trigger signal for system
timing measurements.

Another unique capability of the 62000P Series
supplies is their ability to create complex DC
transient waveforms. This capability allows devices
to be tested to DC voltage dropouts, spikes
and other voltage variations making them an
ideal choice for airborne device testing, inverter
testing and other devices which will experience
voltage interrupts. Applications include DC/DC
Converter & Inverter voltage drop test, engine
start-up simulation, battery automated charging,
electronic product life cycle test, and etc.

PROGRAMMABLE DC POWER SUPPLY
MODEL 62000P SERIES

MODEL 62000P SERIES

Key Features:

Wide range of Voltage & Current

Combinations with Constant Power

Voltage range : 0 ~ 600V

Current range : 0 ~ 120A

Power Range : 600W, 1200W, 2400W, 5000W

Digital Encoder Knobs, Keypad

and Function Keys

Power Factor Correction (0.95)

High-speed Programming

Chroma 62006p-100-25 User Manual

Precision V&I Measurements

Current Sharing for Parallel Operation

with Master/Slave Control

Voltage Ramp Function : Time Range

(10ms~99hours)

Auto Sequencing Programming : 10

Programs / 100 Sequences / 8 bit TTL

Voltage & Current Slew Rate Control

OVP, Current Limit, Thermal Protection

Remote sense, 5V Line Loss Compensation

APG (Analog Programmable Interface)

with Isolated Analog Interface Card

Optional GPIB Control with SCPI

Optional Ethernet/LXI interface

Standard RS-232 & USB Interface

LabView and Labwindows

CE Certified

PFC

Ethernet

GPIB

RS-232

USB

Advertising
Popular Brands
Popular manuals
Advertising

ISO 16750-2 4.5.1 Momentary Drop In
Supply Voltage

Model

62006P-30-80

62006P-100-25

62006P-300-8

62012P-40-120

62012P-80-60

62012P-100-50

Output Ratings
Output Voltage

0~30V

0~100V

0~300V

0~40V

0~80V

0~100V

Output Current

0~80A

0~25A

0~8A

0~120A

0~60A

0~50A

Output Power

600W

600W

600W

1200W

1200W

1200W

Line Regulation
Voltage

0.01%+2mV

0.01%+6mV

0.01%+18mV

0.01%+2mV

0.01%+8mV

0.01%+10mV

Current

0.01%+25mA

0.01%+5mA

0.03%+20mA

0.01%+25mA

0.01%+10mA

0.01%+12mA

Load Regulation
Voltage

0.01%+3mV

0.01%+10mV

0.01%+50mV

0.01%+3mV

0.01%+12mV

0.01%+18mV

Current

0.01%+10mA

0.01%+5mA

0.03%+40mA

0.01%+10mA

0.01%+20mA

0.01%+28mA

Voltage Measurement
Range

6V/30V

20V/100V

60V/300V

8V/40V

16V/80V

20V/100V

Accuracy

0.05% + 0.05%F.S.

0.05% + 0.05%F.S.

0.05% + 0.05%F.S.

0.05% + 0.05%F.S.

0.05% + 0.05%F.S.

0.05% + 0.05%F.S.

Current Measurement
Range

16A/80A

5A/25A

1.6A/8A

24A / 120A

12A/60A

10A/50A

Instruction manual

Accuracy

0.1% + 0.2%F.S.

0.1% + 0.2%F.S.

0.1% + 0.1%F.S.

0.1% + 0.1%F.S..

0.1% + 0.1%F.S.

0.1% + 0.1%F.S.

Output Noise (0 ~ 20MHz)
Voltage Ripple (P-P)

60 mV

85 mV

180 mV

90 mV

100 mV

100 mV

Voltage Ripple (rms)

8 mV

10 mV

90 mV

10 mV

10 mV

15 mV

Current Ripple (rms)

60 mA

10 mA

60 mA

120 mA

30 mA

20 mA

OVP Adjustment Range

110% of Vset to

110% of Vmax

110% of Vset to

110% of Vmax

110% of Vset to

110% of Vmax

110% of Vset to

110% of Vmax

110% of Vset to

110% of Vmax

110% of Vset

to 110% of Vmax

Slew Rate Range
Voltage (with USB)

0.001V - 5V/ms

0.001V - 10V/ms

0.01V - 10V/ms

0.001V - 5V/ms

0.001V - 10V/ms

0.001V - 10V/ms

Current (with USB)

0.001A - 1A/ms

0.001A - 1A/ms

0.001A - 1A/ms

0.001A - 1A/ms

0.001A - 1A/ms

0.001A - 1A/ms

Programming Response Time (Typical)

Rise Time (Full & No Load)

6 ms

10 ms

30 ms

8 ms

8 ms

10 ms

Fall Time

350ms(max)

300 ms(max)

2.5 s(max)

460 ms(max)

240 ms(max)

300 ms(max)

Efficiency

0.75

0.75

0.75

0.8

0.8

0.8

Drift (8 hours)
Voltage

0.02% of Vmax

0.02% of Vmax

0.02% of Vmax

0.02% of Vmax

0.02% of Vmax

0.02% of Vmax

Current

0.04% of Imax

0.04% of Imax

0.04% of Imax

0.04% of Imax

0.04% of Imax

0.04% of Imax

Temperature Coefficient
Voltage

0.02% of Vmax/℃

Chroma 62006p-100-25 manual

0.02% of Vmax/℃

0.02% of Vmax/℃

0.02% of Vmax/℃

0.02% of Vmax/℃

0.02% of Vmax/℃

Current

0.04% of Imax/℃

0.04% of Imax/℃

0.04% of Imax/℃

0.04% of Imax/℃

0.04% of Imax/℃

0.04% of Imax/℃

Transient Response Time

3 mS

3 mS

3mS

3mS

3 mS

3 mS

10 % step change

150 mV

180 mV

600 mV

150 mV

250 mV

250 mV

Voltage limit @ Series Mode

150V

500V

800V

200V

400V

500V

AC Input Voltage Ranges

95 to 250Vac

95 to 250Vac

95 to 250Vac

95 to 250Vac

95 to 250Vac

95 to 250Vac

Operating Temperature

0~40℃

0~40℃

User Manual Pdf

0~40℃

0~40℃

0~40℃

0~40℃

Dimension (H x W x D)

89 x 430 x 425 mm / 3.5 x 16.93 x 16.73 inch

Weight

12kg / 26.43 lbs

12.1 kg / 26.65 lbs

11.2 kg / 24.67 lbs

12kg / 26.43 lbs

13 kg / 28.63 lbs

12.1 kg / 26.65 lbs

All specifications are subject to change without notice. Please visit our website for the most up to date specifications.